ATC-600 Automatic Transfer Switch with 2000amp main breaker & NGR

SKU: 129211
Precio:
$44,676

Gastos de envío calculados en la caja

Stock:
Solo queda 1 unidad
Make an Offer

¿Necesita una respuesta ahora?

Finance

Amount:
Email Finance

Descripción

Condition Used - Like New
Electrical
Amps 2000 amps
Voltage 600 volts
Phase 3-phase
General
Cabinet Type Eaton Freedom 2100 Series
Other Specifications

Automatic Transfer Switch Controller (ATC-60):

Control Power: 120 VAC (50/60 Hz) (operating range 65 to 160 VAC)

Power Consumption: 18 VA

Operating Temperature: -20 to 70 deg. C

Operating Humidity: up to 90% Relative Humidity (non-condensing)

Enclosure Compatibility:

  • NEMA 12 (standard mounting)
  • NEMA 4/4X (mounted with gasket between panel and device faceplate)
  • NEMA 3R (outdoor)
  • UV Resistant ATC-600 Faceplate

System Voltage Application: 120 to 600 VAC (50/60 Hz) (single or three phse)

Voltage Measurements: Source 1, Source 2 and Load (VAB, VBC, VCA for Three Phase System)

Voltage Measurement Range: 0 to 700 VAC

Voltage Measurement Accuracy: +/- 1% of Full Scale

Frequency Measurements: Source 1 and Source 2

Frequency Measurement Range: 40 to 80 Hz

Frequency Measurement Accuracy: +/-0.1 Hz

2x Magne DS Breakers (MDS6203VEA):

Breaker Type (MD): Magnum DS

Frame Type (S): Standard or Double

Interrupting/ withstand rating (6): 65

Continuous Amperes and phasing (facing front of breaker) (20): 2000 ABC

Poles (facing front of breaker) (3): 3

Mounting Configuration and Load Terminals (V): Fixed Vertical

Nameplate Language (E): English

Current Limiter Selection (A): Non-DSL (no limiter)

Main Breaker (RDC320T32W):

Type: New Design 310

Amperage Rating: 200 A

Voltage Rating: 600 VAC

Trip Type: Electronic LSI

Circuit Breaker Type: RDC

Circuit Breaker Frame Type: Complete Breaker

Terminals: with terminals

Interrupt Rating: 65 kAIC @ 480 VAC; 50 kAIC @ 600 VAC

Number of Poles: Three-pole

Neutral Ground Resistor (SE-330):

GF Trip-Level Settings: 2-100% of CT-Primary Rating in 1% increments

GF Trip-Time Settings: 0.1-10s

Vn Trip-Level Settings: 20-2,000 VAC (</-5 kV systems) 100-10,000 VAC (>/-5 kV systems)

Contact Operating Mode: Selectable fail-safe or non-fail-safe (K1, K2, K3)

Harmonic Filtering: Standard feature

Reset Button: Standard feature

Output Contacts: Two form A and Two Form C

Pulsing Circuit: 1.0-3.0s in 0.2s increments

Communications: Mini USB (standard); DeviceNet (optional), IEC 61850 (optional), Modbus TCP and Ethernet/IP (optional)

Analog Input: 4-20 mA, self or loop powered

Conformally Coated: Standard feature

Mounting: Panel and Surface (optional)


Gastos estimados de envío

Pago y seguridad

American Express Apple Pay Diners Club Discover Google Pay Mastercard Shop Pay Visa

Su información de pago se procesa de forma segura. No almacenamos los detalles de la tarjeta de crédito ni tenemos acceso a la información de su tarjeta de crédito.